An effective use of instrumentation in a test setup where asynchronous data is neither repeatablenor consistent is problematic when testing a unit to given test specifications. This defines theelectrical current data taken of a cyclical waveform on an oscilloscope during production testingof a six-step motor drive. The test specification required that a measurement of the total average‘on’ current of the waveform be taken and compared to pass-fail criteria. To resolve this, analgorithm for determining which data points are ‘on’ current versus those ‘off’ current, andaveraging these data points to provide the ‘on’ current values was developed. The data recordedconsisted of data points taken from an oscilloscope single shot picture of the waveform,representing time-varying current output versus time. The effects of noise within theinstrumentation and timing issues added to the complexity of processing the data. The valuesobtained through this algorithm for averaging current correlated well with measurementsobtained from the UUT (Unit Under Test) telemetry and provided consistent, repeatable results.
机译:在异步数据不可重复的测试设置中有效使用仪器 当按照给定的测试规格测试单元时,一致性也不成问题。这定义了 生产测试期间在示波器上从周期性波形中获取的电流数据 六步电机驱动器。测试规范要求对总平均值进行测量 采集波形的“接通”电流,并将其与合格/不合格的标准进行比较。为了解决这个问题, 确定哪些数据点是“接通”电流与那些“断开”电流的算法,以及 对这些数据点取平均值以提供“当前”值。记录的数据 包括从示波器的单次拍摄图片中获取的数据点, 表示时变电流输出与时间的关系。内噪声的影响 仪器和时序问题增加了数据处理的复杂性。价值 通过此算法获得的平均电流与测量值的相关性很好 从UUT(被测单元)遥测获得,并提供一致,可重复的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号