This paper deals with Partial Discharge (PD) measurement technique on the range of high frequency by capacitive sensor for the power cable system. This sensor is installed inside of cable joints and terminations without affecting the insulation design. The sensitivity of the sensor depending on the installtion condition was investigated by simulation and compared with the results of experiments with joint occurring PD. It was shown that the dominant factor affecting sensitivity of sensor was resistance formed between sensor and ground sheath. It was proven that the sensitivity of this sensor was much higher than that of the conventional method in accordance with IEC270 standard. And this sensor is available technique for the on-line PD monitoring system.
机译:本文探讨了电容电缆在电力电缆系统中高频范围内的局部放电(PD)测量技术。该传感器安装在电缆接头和端子的内部,不会影响绝缘设计。通过仿真研究了传感器的灵敏度(取决于安装条件),并将其与联合发生PD的实验结果进行了比较。结果表明,影响传感器灵敏度的主要因素是传感器与接地护套之间形成的电阻。事实证明,该传感器的灵敏度远高于符合IEC270标准的常规方法。该传感器是在线局部放电监测系统的可用技术。