摘要

Open path is a measurement technique that quantifies the presence of gas over long distances. The long path lengths used provide significant sensitivity and coverage advantages over point source ambient pollution monitoring. A second consequence of this long path length is confusing, variable, and poorly understood specifications. This work reviews the three major open path technologies, and the measurement errors associated in each specific- case. Practical measurement limits are found. These are based on factors encountered in the field such as alignment and humidity as opposed to random error measured under controlled conditions. Optimal performance of these instruments is predicted with respect to the two adjustable variables, path length and integration time.
机译:开放路径是一种测量技术,可以量化长距离气体的存在。与点源环境污染监测相比,所使用的长路径长度提供了显着的灵敏度和覆盖范围优势。如此长的路径长度的第二个结果是令人困惑,易变且难以理解的规范。这项工作回顾了三种主要的开放路径技术,以及每种情况下的测量误差。找到实际的测量极限。这些是基于本领域遇到的因素,例如对齐和湿度,而不是在受控条件下测得的随机误差。这些仪器的最佳性能是根据两个可调变量(路径长度和积分时间)预测的。