首页> 外文会议> >Measurement of voltage rise curves due to gap discharge using coupled transmission lines in distributed constant line system
【24h】

Measurement of voltage rise curves due to gap discharge using coupled transmission lines in distributed constant line system

机译:使用分布式恒定线系统中的耦合传输线测量间隙放电引起的电压上升曲线

获取原文

摘要

Very fast voltage rise curves due to gap discharge were examined to discuss an EMI source. The measurement system consists of a distributed constant line system, because the voltage transients were very rapid. A characteristic of the gap electrode, which has a matched impedance for the distributed constant line system, was investigated in the frequency range below 5 GHz. The voltages of the power source in the experiment were 510 V and 800 V because Paschen's law holds its stability in the air condition. It was confirmed that the measurement method enables one to measure high speed voltage rise curves of about 100 ps.
机译:检查了由于间隙放电而产生的非常快的电压上升曲线,以讨论EMI源。由于电压瞬变非常迅速,因此测量系统由分布式恒定线路系统组成。在低于5 GHz的频率范围内,对间隙电极的特性进行了研究,该间隙电极具有与分布式恒定线系统匹配的阻抗。实验中电源的电压分别为510 V和800 V,因为帕申定律在空气条件下保持稳定。证实了该测量方法使人们能够测量大约100 ps的高速电压上升曲线。