首页> 外文会议>1997 International Symposium on Electromagnetic Compatibility 1997, Beijing, China >Measurement of Voltage Rise Curves DUE to GAP Discharge Using Coupled Transmission Lines in Distributed Constant Line System
【24h】

Measurement of Voltage Rise Curves DUE to GAP Discharge Using Coupled Transmission Lines in Distributed Constant Line System

机译:分布式恒定线路系统中使用耦合传输线测量由于GAP放电引起的电压上升曲线

获取原文
获取原文并翻译 | 示例

摘要

Very fast voltage rise curves due to gap discharge were examined discuss a EMI source. The measurement system consists of a distributed constant line system, because the voltage transients were ver rapid. A characteristic of the gap electrode, which has a matched impedance for the distributed constant line system, was investigated in the freqeuncy range below 5GHz. The voltages of power source in experiment were 510V and 800V bcause the Paschen's law holds stability in air condition. It was confinned that the measurement method enables to measure the high speed voltage rise curves of about 100ps.
机译:讨论了由间隙放电引起的非常快的电压上升曲线,并讨论了EMI源。测量系统由分布式恒定线路系统组成,因为电压瞬变非常迅速。在低于5GHz的频率范围内,对间隙电极的特性进行了研究,该电极具有与分布式恒定线系统匹配的阻抗。实验中的电源电压分别为510V和800V,这是因为帕申定律在空调中保持稳定。可以确定,该测量方法能够测量大约100ps的高速电压上升曲线。