首页> 外文会议> >Canceling the wall contamination using Doppler ultrasound signals from two consecutive cardiac cycles
【24h】

Canceling the wall contamination using Doppler ultrasound signals from two consecutive cardiac cycles

机译:使用来自两个连续心动周期的多普勒超声信号消除壁污染

获取原文

摘要

An approach is presented to cancel the arterial wall contamination using audio Doppler ultrasound signals from two consecutive cardiac cycles. The wall signal is approximately periodic, while the Doppler signal from the blood flow is random because the scatters within the ultrasound sample volume are continually updated. Thus, the signal subtraction between two consecutive cardiac cycles is carried out in time domain. Simulated Doppler signals from a normal femoral artery with various clutter to blood ratios are used to validate this approach. The conventional high-pass filtering method is also carried out for comparison. The experimental results show that this approach may be a good solution for the 'wall thump' removal when there is few difference of the wall movement between the two consecutive cardiac cycles.
机译:提出了一种使用来自两个连续心动周期的音频多普勒超声信号消除动脉壁污染的方法。壁信号大约是周期性的,而来自血流的多普勒信号是随机的,因为超声样本体积内的散射会不断更新。因此,两个连续的心动周期之间的信号减法在时域中进行。来自正常股动脉的杂波与血流比率不同的模拟多普勒信号用于验证该方法。为了比较,还执行了常规的高通滤波方法。实验结果表明,当两个连续心动周期之间的壁运动差异很小时,这种方法可能是去除“壁wall”的好方法。