Use of chemiluminescence techniques in portable lightweight highly sensitive instruments for measuring NO2 NOx and O3

机译:化学发光技术在便携式轻型高灵敏仪器中用于测量NO2,NOx和O3的用途

获取原文
获取原文并翻译 | 示例

摘要

Abstract: Small battery powered instruments for the sensitive detection of nitrogen dioxide (NO$-2$/), and ozone (O$-3$/) will be described. Because of their portability, they are ideal for studies of indoor air quality, measurements for aircraft, and other mobile platforms where power may be limited. For example, a miniature balloon borne sonde, based on the chemiluminescence between luminol and NO$-2$/ has recently demonstrated the ability to measure ambient mixing ratios of NO$-2$/ between ground level and an altitude of 33 km. The recent 'add-on's to the model LMA-3 NO$-2$/ analyzer are discussed. These include NO$-x$/ converters, techniques for eliminating the residual ozone and PAN interferences, as well as removing nonlinearity for mixing ratios of less than one ppbV. Finally, the model LOZ-4 ozone monitor will be described. Ozone is measured by using its chemiluminescence with the dye Eosin Y. In comparison with ethylene based ozone detectors, the LOZ-4 has better sensitivity, and does not require a troublesome and flammable gas. The O$-3$/ measurement is virtually interference free. In contrast, the widely used photometric O$-3$/ measurement technique has demonstrated significant interferences in polluted air (presumably due to organic compounds that absorb light at the 253.7 nm wavelength). Field measurements for all species are presented.!
机译:摘要:将描述小型电池供电的仪器,用于灵敏地检测二氧化氮(NO $ -2 $ /)和臭氧(O $ -3 $ /)。由于它们的便携性,它们非常适合用于研究室内空气质量,飞机和其他功率可能受限的移动平台的测量。例如,基于鲁米诺和NO $ -2 $ /之间化学发光的微型气球探测仪最近证明了能够测量地面和33 km高度之间NO $ -2 $ /的环境混合比。讨论了LMA-3 NO $ -2 $ /分析仪的最新“附加组件”。其中包括NO $ -x $ /转换器,消除残留臭氧和PAN干扰的技术,以及消除混合比小于1 ppbV的非线性的技术。最后,将描述LOZ-4型臭氧监测仪。臭氧通过与染料曙红Y一起化学发光来测量。与基于乙烯的臭氧检测器相比,LOZ-4具有更好的灵敏度,并且不需要麻烦和易燃气体。 O $ -3 $ /测量值几乎没有干扰。相反,广泛使用的光度O $ -3 $ /测量技术显示出对污染空气的显着干扰(大概是由于有机化合物吸收了253.7 nm波长的光)。介绍了所有物种的实地测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号