首页> 外文会议>IWA(International Water Association) International Conference on Odours and VOCs; 20030914-17; Singapore(SG) >Effect of back-pressure on absorption efficiency of impingers used for air sampling
【24h】

Effect of back-pressure on absorption efficiency of impingers used for air sampling

机译:背压对用于空气采样的冲击器吸收效率的影响

获取原文
获取原文并翻译 | 示例

摘要

The gas-liquid absorption method, using an impinger as an extracting device, is the most common method for quantifying most gaseous pollutants. The performance of conventional impingers was studied, and several modified impingers were tested. It was found that the sampling efficiency varied from impinger to impinger, which resulted from back-pressure differences between impingers. The back-pressure of ten tested impingers ranged between 160 mm to 520 mm water gage when a 50 ml absorbing solution was used, which caused the ammonia concentration coefficients of variations to be up to 15%. It was also verified that an open bubble distribution tube could be used to eliminate back-pressure variations between impingers. Nearly identical back-pressure (44 ± 4 mm water gage) could be obtained. This modification can improve measurement repeatability significantly and reduce the coefficient of variation of measurements to 1.2%. With this modification to the impingers, greater accuracy, repeatability and comparison of results can be achieved in the measurement of gaseous pollutants in air.
机译:使用撞击器作为提取装置的气液吸收法是定量大多数气态污染物的最常用方法。研究了常规撞击器的性能,并测试了几种改进的撞击器。结果发现,采样效率因冲击器而异,这是由于冲击器之间的背压差引起的。当使用50 ml吸收液时,十个测试的撞击器的背压在160 mm至520 mm水表之间,这会导致氨浓度变异系数高达15%。还证实了可以使用开放式气泡分配管消除冲击器之间的背压变化。可以获得几乎相同的背压(44±4毫米水位计)。这种修改可以显着提高测量的可重复性,并将测量的变化系数降低到1.2%。通过对撞击器的这种修改,可以在测量空气中的气态污染物时实现更高的准确性,可重复性和结果比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号