The concept of "equipotential bonding" had been an important principle in EMC design. Based on the circuit approach, this paper investigates the distribution of the node voltage on such building structures during a direct lightning stroke. The simulation results have shown that the concept of "equipotential bonding" is only applicable in a limited area. The effectiveness of the equipotential bonding measures depends on the connecting way of the ground wire of the equipment. Some suggestions for effective equipotential bonding are also given.
机译:“等电位连接”的概念一直是EMC设计中的重要原则。基于电路方法,本文研究了直接雷击期间此类建筑结构上节点电压的分布。仿真结果表明,“等电位连接”的概念仅适用于有限的区域。等电位联结措施的有效性取决于设备接地线的连接方式。还提出了有效等电位键合的一些建议。