首页> 外文会议>Ignorance, uncertainty and human errors in structural engineering >Structural Safety Assessment of a Suspension Bridge using Analysis Model Updating
【24h】

Structural Safety Assessment of a Suspension Bridge using Analysis Model Updating

机译:应用分析模型更新的悬索桥结构安全性评估

获取原文
获取原文并翻译 | 示例

摘要

A reduction in concrete compressive strength is detected in the main tower of a suspensionrnbridge. Since this strength is below the design strength, structural safety assessment is required.rnAmbient vibration tests (AVTs) were performed to identify current dynamic of the bridge with 56rndense installation point of accelerometers. Manual tuning method is applied to update analysisrnmodel based on measured dynamic properties. As a result, errors between the analysis andrnmeasurement of the natural frequencies are reduced from 9% to 4%. Automated model updatingrnmethod with sensitivity-based optimization is additionally applied to update analysis model.rnFinally, update model has errors of natural frequencies below 2%. Utilizing the updated model,rnstructural safety assessment is performed considering live load, wind load and seismic load.
机译:在悬索桥的主塔中检测到混凝土抗压强度降低。由于该强度低于设计强度,因此需要进行结构安全评估。进行了环境振动测试(AVT),以识别加速度计56致密安装点的桥梁的当前动态。基于测量的动态特性,采用手动调整方法更新分析模型。结果,分析和测量固有频率之间的误差从9%降低到4%。最后,采用基于灵敏度的优化的自动模型更新方法来更新分析模型。最后,更新模型的固有频率误差低于2%。利用更新的模型,考虑活荷载,风荷载和地震荷载进行结构安全评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号