首页> 外文会议>IEEE SENSORS Conference >Compact Fiber Optic Sensors for Dual Temperature and Refractive Index Profiling Based on Partially Etched Chirped Fiber Bragg Grating
【24h】

Compact Fiber Optic Sensors for Dual Temperature and Refractive Index Profiling Based on Partially Etched Chirped Fiber Bragg Grating

机译:基于部分蚀刻Chi光纤布拉格光栅的双温度和折射率分布的紧凑型光纤传感器

获取原文

摘要

We propose a partially etched chirped fiber Bragg grating (pECFBG) as a fiber optic sensor capable of detecting and profiling temperature and refractive index changes over the grating length. The sensor is achieved by etching a 1.4 cm-long chirped FBG by hydrofluoric acid, leaving a part of the grating unetched. In this way, we expose a part of the grating to refractive index variations in the outer medium, while the whole grating is sensitive to temperature changes. By applying spectral correlation in each grating portion, it is possible to detect profiles of temperature and refractive index, as experimentally demonstrated.
机译:我们提出了一种部分蚀刻的chi光纤布拉格光栅(pECFBG)作为能够检测和分析光栅长度上的温度和折射率变化的光纤传感器。传感器是通过用氢氟酸蚀刻一个1.4厘米长的chi FBG来实现的,而光栅的一部分未被蚀刻。这样,我们将光栅的一部分暴露在外部介质的折射率变化中,而整个光栅对温度变化敏感。通过在每个光栅部分中应用光谱相关性,可以检测到温度和折射率的分布,如实验所示。