New electronic current transformers (ECTs) often adopt a circular array of magnetic sensors for the large current measurement without iron cores. However, the position of this ECT on the measured conductor will directly influence the current measurement accuracy. In this study, we build a 3-D magnetic-field model which is used to analyze the impact of the magnetic-sensor circular array position on current measurement. To meet the accuracy Class 1.0, we estimate the necessary magnetic sensor number and the acceptable position deviation of the ECT. Finally, a new ECT with the circular array of seven magnetic sensors is designed and implemented, which is used to validate the simulation analysis of the ECT position deviation.
机译:新型电子电流互感器(ECT)通常采用圆形的磁传感器阵列来进行大电流测量,而无需使用铁芯。但是,此ECT在被测导体上的位置将直接影响电流测量精度。在这项研究中,我们建立了一个3-D磁场模型,该模型用于分析磁传感器圆形阵列位置对电流测量的影响。为了达到精度等级1.0,我们估算必要的磁传感器数量和ECT的可接受位置偏差。最后,设计并实现了具有七个磁传感器的圆形阵列的新ECT,用于验证ECT位置偏差的仿真分析。