首页> 外文会议>IEEE International Symposium on Circuits and Systems;ISCAS 2009 >Design and implementation of a Low-power Intensity Pulsed-Ultrasound generator for dental tissue regeneration
【24h】

Design and implementation of a Low-power Intensity Pulsed-Ultrasound generator for dental tissue regeneration

机译:用于牙科组织再生的低功率强度脉冲超声发生器的设计与实现

获取原文

摘要

This paper presents the design and implementation of a Low-Intensity Pulsed Ultrasound (LIPUS) generator for dental tissue regeneration. It consists of a power supply subsystem, an ultrasonic transducer, an impedance-matching circuit and an integrated circuit consisting of digital controller circuitry and driver circuit. The integrated circuit was designed and fabricated using 0.8 mum High-Voltage Technology from Dalsa Semiconductor Inc. The power supply sub-system and impedance matching network are implemented using discrete components. Upon construction, the LIPUS generator was verified to function correctly and is capable of producing LIPUS power upwards of 100 mW in the vicinity of the transducer';s resonance frequency. Power efficiency of the circuitry, excluding the power supply sub-system, is estimated at 70%.
机译:本文介绍了用于牙科组织再生的低强度脉冲超声(LIPUS)发生器的设计和实现。它由电源子系统,超声换能器,阻抗匹配电路和由数字控制器电路和驱动器电路组成的集成电路组成。该集成电路是使用Dalsa Semiconductor Inc.的0.8毫米高压技术设计和制造的。电源子系统和阻抗匹配网络是使用分立组件实现的。在构造时,LIPUS发生器经过验证可正常工作,并且能够在换能器的谐振频率附近产生高达100 mW的LIPUS功率。电路的电源效率(不包括电源子系统)估计为70%。