首页> 外文会议>IEEE International Power Electronics and Application Conference and Exposition >Adaptive Harmonic Current Compensation Method with SAPF based on SOGI
【24h】

Adaptive Harmonic Current Compensation Method with SAPF based on SOGI

机译:基于SOGI的SAPF自适应谐波电流补偿方法

获取原文

摘要

The shunt active power filter (SAPF) cannot compensate harmonic and reactive current completely when capacity is limited. Aiming at the problem, an adaptive harmonic compensation control method based on second order generalized integrator (SOGI) is proposed with calculating APF's capacity strictly. SOGI is used to extract the harmonic currents as instruction current. RDFT algorithm is used to calculate the RMS of each harmonic component. According to the SAPF's capacity, the selective harmonic components to compensate and the corresponding ratio is adjusted adaptively. The PI and repetitive compound control strategy is used to track the compensation current accurately. Simulation analysis and experiments show that the stated method has obvious superiority in control simplicity and capacity utilization of SAPF.
机译:当容量受限时,并联有功功率滤波器(SAPF)无法完全补偿谐波和无功电流。针对该问题,提出了一种基于二阶广义积分器(SOGI)的自适应谐波补偿控制方法,该方法严格计算了APF的容量。 SOGI用于提取谐波电流作为指令电流。 RDFT算法用于计算每个谐波分量的RMS。根据SAPF的容量,可以自适应地调整要补偿的选择性谐波分量和相应的比率。 PI和重复复合控制策略用于精确跟踪补偿电流。仿真分析和实验表明,该方法在控制简单性和SAPF容量利用率方面具有明显的优越性。