首页> 外文会议>IEEE International Power Electronics and Application Conference and Exposition >The Current Loop Stability Investigation under Zero Ripple Current Mode Applied for the Interleaved Active Clamp Forward Converter
【24h】

The Current Loop Stability Investigation under Zero Ripple Current Mode Applied for the Interleaved Active Clamp Forward Converter

机译:交错有源钳位正激变换器在零纹波电流模式下的电流环路稳定性研究

获取原文

摘要

In this paper, the loop instability issue regarding the inner current loop used in the interleaved parallel-series active clamp forward (ACF) has been addressed, which occurs mostly under the condition of Zero output ripple current when D approaches 0.5. To have a full investigation, the small signal model regarding the inner current Loop is proposed for the analysis, based on which the criterion and the design tips targeting to achieve the loop stability have been proposed and elaborated. Finally, the measurement based on LM5034 related application has been conducted for the verification. It is shown that the proposed solution agrees well with measurement.
机译:本文解决了交错式并联串联有源钳位正激(ACF)中使用的内部电流环路的环路不稳定性问题,该问题主要在D接近0.5时输出纹波电流为零的情况下发生。为了进行全面研究,提出了有关内部电流环路的小信号模型进行分析,并在此基础上提出并阐述了实现环路稳定性的标准和设计技巧。最后,基于LM503​​4相关应用进行了测量以进行验证。结果表明,所提出的解决方案与测量结果吻合良好。