首页> 外文会议>IEEE International Conference on Environment and Electrical Engineering;IEEE Industrial and Commercial Power Systems Europe >Increasing Water Pump Station Throughput by Introducing VFD-Based IE4 Class Synchronous Reluctance Motors with Improved Pump Control
【24h】

Increasing Water Pump Station Throughput by Introducing VFD-Based IE4 Class Synchronous Reluctance Motors with Improved Pump Control

机译:通过引入具有改进的泵控制功能的基于VFD的IE4类同步磁阻电机来提高水泵站的吞吐量

获取原文

摘要

/hr and servicing a head of 80m is studied, with the results following an energy efficiency upgrade being reported on. Energy efficiency is quantified by employing the International Performance Measurement and Verification Protocol (IPMVP) on the holistic system as opposed to the measurement of individual components as outlined in, amongst other standards for other components, the test methods for determining losses and efficiency of VSD-fed motors IEC 60034-2-3. The IPMVP protocol further provides the parameters for quantifying specific energy consumption improvement of a complete pump system. The pump system supplies water for public use in the northern region of South Africa. An overall energy saving of 36% for the complete pumping system is reported whilst maintaining unchanged water delivery; alternatively water pump station throughput can be increased by 58% without increasing energy consumption.
机译:/ hr并研究了80m的水头,并报告了提高能效之后的结果。通过在整体系统上采用国际性能测量和验证协议(IPMVP)来量化能效,这与其他组件的其他标准(用于确定VSD的损耗和效率的测试方法)中概述的单个组件的测量相反电机IEC 60034-2-3。 IPMVP协议还提供了用于量化完整泵系统的特定能耗改善的参数。泵系统为南非北部地区的公共供水。据报道,整个抽水系统的整体节能量为36%,同时保持不变的供水量;另外,在不增加能耗的情况下,水泵站的吞吐量可以提高58%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号