首页> 外文会议>IEEE Information Technology, Networking, Electronic and Automation Control Conference >Automation and control design of overvoltage protection for sub-modules in modular multilevel converter
【24h】

Automation and control design of overvoltage protection for sub-modules in modular multilevel converter

机译:模块化多电平转换器子模块过压保护的自动化与控制设计

获取原文

摘要

Different IGBT packaging methods and failure mechanisms of the modular multilevel converter (MMC) are described. The working principle of sub-modules before and after the fault and the closing of the bypass switch is analyzed. The working principle of overvoltage protection for sub-modules in different IGBT packaging modes is introduced, including overvoltage protection, triggering underneath IGBT overvoltage protection and overvoltage tripping protection which are aimed at bond wired IGBT modules, and overvoltage protection aimed at press-pack IGBTs for average voltage of capacitor on bridges. Overvoltage protection strategy of bond wired IGBT modules has the risk of converter tripping due to abnormal voltage sampling. To this end, the optimized design of overvoltage protection strategy for sub-modules is presented. The optimized strategy is implemented in sub-module control board, which is easy to be implemented with less program resources. The system overvoltage criterion is proposed to avoid bypassing the sub-module in the case of system overvoltage.
机译:描述了模块化多电平转换器(MMC)的不同IGBT封装方法和故障机理。分析了故障及旁路开关闭合前后子模块的工作原理。介绍了不同IGBT封装模式下子模块的过压保护的工作原理,包括过压保护,针对底层引线触发的IGBT过压保护和过压跳闸保护,其针对键合线IGBT模块,以及针对压装IGBT的过压保护。电桥上电容器的平均电压。键合接线的IGBT模块的过压保护策略具有因异常电压采样而导致转换器跳闸的风险。为此,提出了子模块过压保护策略的优化设计。优化策略在子模块控制板上实现,易于实现,程序资源更少。提出系统过电压准则是为了避免在系统过电压的情况下绕过子模块。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号