首页> 外文会议>Ground engineering in a changing world >Evaluation of Effectiveness of Soil Gas and Groundwater Monitoring for Underground Storage Tanks
【24h】

Evaluation of Effectiveness of Soil Gas and Groundwater Monitoring for Underground Storage Tanks

机译:地下储罐土壤气和地下水监测有效性评估

获取原文
获取原文并翻译 | 示例

摘要

Potential of leakage of a underground storage tank (UST) of gasoline station increases with its servicernlife. In order to avoid serious pollution caused by the dissolution of toxic constituents in LNAPLs (Lightrnnon-aqueous phase liquids), monitoring measures are employed to provide early warning. Among thernmonitoring methods, soil gas and groundwater monitoring detect the leaked product directly. Thernpathway of leaked gasoline flows and diffuses and thus, in turn the effectiveness of soil gas andrngroundwater monitoring, may be affected by the existence of USTs of gasoline station. In this study,rnnumerical simulation with the software TMVOC was performed in order to assess the effectiveness ofrnsoil gas and groundwater monitoring. The results show that both soil gas and groundwater monitoringrnare more effective if the site has a shallow groundwater table and the soil has higher hydraulicrnconductivity and lower porosity. The effectiveness of soil gas monitoring is better than groundwaterrnmonitoring in general, when soil gas and groundwater monitor well are far away leakage then therngroundwater monitoring is better than soil gas.
机译:加油站地下储油罐(UST)的泄漏潜力随其使用寿命而增加。为了避免由于有毒成分在LNAPL(轻质非水相液体)中的溶解而造成的严重污染,采用了监测措施来提供预警。在监测方法中,土壤气体和地下水监测直接检测泄漏的产物。汽油泄漏的途径流动和扩散,因此,土壤气和地下水监测的有效性可能受到加油站USTs的影响。在这项研究中,使用软件TMVOC进行了数值模拟,以评估土壤气和地下水监测的有效性。结果表明,如果该场地地下水位较浅,且土壤的水力传导率较高且孔隙度较低,则土壤气和地下水监测都将更为有效。一般而言,土壤气监测的有效性要优于地下水监测,当土壤气和地下水监测井远离泄漏时,地下水监测要优于土壤气。

著录项

  • 来源
  • 会议地点 Melbourne(AU)
  • 作者

    Hsin-yu Shan; Pei-min Chen;

  • 作者单位

    Department of Civil Engineering, National Chiao Tung University,1001 Ta Hsueh Road, Hsinchu City, Taiwan, PH +886 3 513 1562, FAX +886 3 571 6257, email: hyshan@mail.nctu.edu.tw;

    Apollo Technology, Co., Ltd. 15F-1, No. 421, Sung Shan Road, Taipei City, Taiwan, PH +886 2 2726 2099, FAX +886 2 2726 2037, email: miller2237@hotmail.com;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    LNAPL; underground storage tank; soil vapour monitoring;

    机译:LNAPL ;;地下储罐;;土壤蒸气监测;