Optical Coherence Tomography Technique For Noninvasive Blood Glucose Monitoring: Phantom, Animal, and Human Studies

机译:用于无创血糖监测的光学相干断层扫描技术:幻影,动物和人体研究

获取原文
获取原文并翻译 | 示例

摘要

Continuous noninvasive monitoring of blood glucose concentration can improve management of Diabetes Mellitus, reduce mortality, and considerably improve quality of life of diabetic patients. Recently, we proposed to use the OCT technique for noninvasive glucose monitoring. In this paper, we tested noninvasive blood glucose monitoring with the OCT technique in phantoms, animals, and human subjects. An OCT system with the wavelength of 1300 nm was used in our experiments. Phantom studies performed on aqueous suspensions of polystyrene microspheres and milk showed 3.2% decrease of exponential slope of OCT signals when glucose concentration increased from 0 to 100 mM. Theoretical calculations based on the Mie theory of scattering support the results obtained in phantoms. Bolus glucose injections and glucose clamping experiments were performed in animals (New Zealand rabbits and Yucatan micropigs). Good correlation between changes in the OCT signal slope and actual blood glucose concentration were observed in these experiments. First studies were performed in healthy human subjects (using oral glucose tolerance tests). Dependence of the slope of the OCT signals on the actual blood glucose concentration was similar to that obtained in animal studies. Our studies suggest that the OCT technique can potentially be used for noninvasive blood glucose monitoring.
机译:连续无创监测血糖浓度可以改善糖尿病的管理,降低死亡率,并显着改善糖尿病患者的生活质量。最近,我们提出将OCT技术用于无创血糖监测。在本文中,我们使用OCT技术在幻像,动物和人类受试者中测试了无创血糖监测。在我们的实验中使用了波长为1300 nm的OCT系统。对聚苯乙烯微球和牛奶的水悬浮液进行的幻影研究表明,当葡萄糖浓度从0增加到100 mM时,OCT信号的指数斜率降低了3.2%。基于米氏散射理论的理论计算支持幻像中获得的结果。在动物(新西兰兔和尤加坦微型猪)中进行了小块葡萄糖注射和葡萄糖钳制实验。在这些实验中,OCT信号斜率的变化与实际血糖浓度之间存在良好的相关性。最初的研究在健康的人类受试者中进行(使用口服葡萄糖耐量试验)。 OCT信号的斜率对实际血糖浓度的依赖性与在动物研究中获得的类似。我们的研究表明,OCT技术可以潜在地用于无创血糖监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号