Abstract: This paper is concerned with enhancing the accuracy of the coordinate measurement system by compensating the Abbe error in real-time through combined gratings. This research is carried out on a 2D measuring system with a maximum moving range of 200mm $MUL 100mm. According to its structure, a mathematical model using the rigid body assumption is deduced and altogether five metrology gratings are installed along two moving axes to compensate three angel errors according to this model. A special grating subdividing system is designed to realize 200 times subdivision for each of the five gratings. Experiment shows that this system can largely raise the accuracy of the coordinate measurement device. Besides, this research is also very valuable in the upgrading of machine tools. !8
机译:摘要:本文涉及通过组合光栅实时补偿阿贝误差来提高坐标测量系统的精度。这项研究是在最大移动范围为200mm $ MUL 100mm的2D测量系统上进行的。根据其结构,推导了使用刚体假设的数学模型,并沿两个移动轴总共安装了五个计量光栅,以根据该模型补偿三个天使误差。设计了一种特殊的光栅细分系统,以实现对五个光栅中每个光栅的200倍细分。实验表明,该系统可以大大提高坐标测量仪的精度。此外,这项研究对机床的升级也非常有价值。 !8