首页> 外文期刊>Applied optics >Compensation for straightness measurement systematic errors in six degree-of-freedom motion error simultaneous measurement system
【24h】

Compensation for straightness measurement systematic errors in six degree-of-freedom motion error simultaneous measurement system

机译:六自由度运动误差同时测量系统中直线度测量系统误差的补偿

获取原文
获取原文并翻译 | 示例
       

摘要

The straightness measurement systematic errors induced by error crosstalk, fabrication and installation deviation of optical element, measurement sensitivity variation, and the Abbe error in six degree-of-freedom simultaneous measurement system are analyzed in detail in this paper. Models for compensating these systematic errors were established and verified through a series of comparison experiments with the Automated Precision Inc. (API) 5D measurement system, and the experimental results showed that the maximum deviation in straightness error measurement could be reduced from 6.4 to 0.9 mu m in the x-direction, and 8.8 to 0.8 mu m in the y-direction, after the compensation. (C) 2015 Optical Society of America
机译:本文详细分析了误差串扰,光学元件的制造和安装偏差,测量灵敏度变化以及六个自由度同时测量系统中的阿贝误差引起的直线度测量系统误差。建立了用于补偿这些系统误差的模型,并通过与Automated Precision Inc.(API)5D测量系统进行的一系列比较实验进行了验证,实验结果表明,直线度误差测量的最大偏差可以从6.4减小到0.9μm补偿后,在x方向上为m,在y方向上为8.8至0.8μm。 (C)2015年美国眼镜学会