首页> 外文会议>Architecture of Computing Systems - ARCS 2011 >Application-Aware Power Saving for Online Transaction Processing Using Dynamic Voltage and Frequency Scaling in a Multicore Environment
【24h】

Application-Aware Power Saving for Online Transaction Processing Using Dynamic Voltage and Frequency Scaling in a Multicore Environment

机译:在多核环境中使用动态电压和频率缩放功能实现在线交易处理的应用程序感知节能功能

获取原文
获取原文并翻译 | 示例

摘要

Power consumption in data centers has been growing remarkably recent years, and power saving of their servers is essential. For power saving of these servers, power saving of an online transaction processing (OLTP) systems, which are major applications in data centers, is important. The OLTP system consumes relatively large amount of power because it is often equipped with a lot of computing and storage resources. Its power saving is difficult because it is required to meet a service level agreement (SLA), and few power saving technologies have been proposed so far. In this paper, we proposed an application-aware power saving for OLTP in a multicore environment. Our proposed methodology aims to save power consumption of OLTP systems by dynamically scaling the operating frequency of processors based on response time observation. Response time is often an important metric of SLA. Application-aware power saving enables power saving in such systems subject to SLAs. In our experimental evaluations using industrial standard benchmark TPC-C and real server workloads, 7.6% of total power consumption was saved. This reduction corresponds to lOOOkJ a day in a typical entry level server. database system, multicore, online transaction processing, power saving, application aware, service level agreement, dynamic voltage and frequency scaling.
机译:近年来,数据中心的功耗一直在显着增长,节省服务器功耗至关重要。为了节省这些服务器的电量,重要的是节省数据中心主要应用程序在线事务处理(OLTP)系统的电量。 OLTP系统通常会配备大量计算和存储资源,因此会消耗相对大量的功率。由于需要满足服务水平协议(SLA),因此很难实现节电,并且到目前为止,很少有人提出节电技术。在本文中,我们提出了在多核环境中OLTP的应用感知节能功能。我们提出的方法旨在通过根据响应时间观察动态缩放处理器的工作频率来节省OLTP系统的功耗。响应时间通常是SLA的重要指标。感知应用程序的节能功能可在受SLA约束的此类系统中实现节能功能。在我们使用行业标准基准TPC-C和真实服务器工作负载进行的实验评估中,节省了7.6%的总功耗。在典型的入门级服务器中,这种减少相当于每天100千焦耳。数据库系统,多核,在线事务处理,节电,应用感知,服务水平协议,动态电压和频率缩放。

著录项

  • 来源
  • 会议地点 Como(IT);Como(IT)
  • 作者单位

    Institute of Industrial Science, the University of Tokyo 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 Japan;

    Institute of Industrial Science, the University of Tokyo 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 Japan;

    Institute of Industrial Science, the University of Tokyo 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 Japan;