首页> 外文会议>日本建築学会;日本建築学会大会 >Durability and Seismic Resistance of an Aged Precast Prestressed Concrete Building (Part 1: Field Inspections and Laboratory Testing)
【24h】

Durability and Seismic Resistance of an Aged Precast Prestressed Concrete Building (Part 1: Field Inspections and Laboratory Testing)

机译:旧的预制预应力混凝土建筑物的耐久性和抗震性(第1部分:现场检查和实验室测试)

获取原文

摘要

The former Nandan city hall building exhibited asatisfactory 60 years of service. Shaken by big scaleearthquakes and exposed to corrosive environment, thisbuilding showed no serious damage in the in-situ inspection.Some serious signs of corrosion at anchorages were noticed.Chloride content was below the threshold limits andcarbonation in PC beams was insignificant. The largecarbonation depth at some concrete core samples of thecolumns, walls, and RC beams implied the initiation ofcorrosion of embedded steel bars.
机译:前南丹市政厅大楼的服务水平令人满意,已有60年历史。该建筑物因大规模地震而震动并暴露在腐蚀性环境中,在现场检查中未显示出严重损坏,在锚地处发现了一些严重的腐蚀迹象,氯化物含量低于阈值极限,PC梁中的碳化微不足道。某些混凝土核心柱,墙和RC梁的大碳化深度暗示了嵌入式钢筋的腐蚀开始。