Multicomponent Infrared Gas analyzers have been a workhorse as Continuous Emissions Monitoring Systems (CEMS) in the waste-to-energy (WTE) application for the past two decades. It is the technique of choice for many facilities. With obsolescence for electronics, instrumentation and data acquisition systems (DAS) averaging less than 10 years, the earlier multicomponent CEMS are being upgraded to what is now a third generation of that technology. This paper describes the evolution of the three generations of multicomponent CEMS. The evaluation of this technology in the WTE application encompasses the operating histories of nearly two dozen facilities demonstrating compliance with this type of CEMS. Specific details explaining the sampling systems, analyzer optics & controls, interface and communication with plant distributed control systems, and DAS systems are presented. Relative accuracy test audit (RATA) results, CEMS availability histories and annual maintenance costs are reviewed presenting a unique insight into both initial capital costs and operating costs. Actual annual man-hour totals for preventive maintenance (PM), unscheduled maintenance, and annual consumable parts costs are provided. Advances in computer capabilities have provided an opportunity for CEMS functions to not only become more comprehensive but also more robust. Key among these advances is the ability for factory-support services to be provided not only for the software platform but now even down to the basic auditing parameters of the analyzers themselves. Third generation CEMS now feature remote access of the analyzers from the instrumentation repair shop, the vendor's factory or from the company's technical service center.
机译:在过去的二十年中,多组分红外气体分析仪一直是废物转化为能源(WTE)应用中的连续排放监控系统(CEMS)的主力军。这是许多设施的首选技术。随着电子,仪器和数据采集系统(DAS)的淘汰平均不到10年,较早的多组件CEMS正在升级为现在的第三代技术。本文介绍了三代多组分CEMS的发展。在WTE应用程序中对该技术的评估涵盖了近两打设施的运行历史,这些设施证明符合此类CEMS。提供了详细的详细信息,说明了采样系统,分析仪的光学和控件,与工厂分布式控制系统以及DAS系统的接口和通讯。审查了相对准确度测试审核(RATA)结果,CEMS可用历史记录和年度维护成本,从而提供了对初始资本成本和运营成本的独特见解。提供了预防性维护(PM),计划外维护和年度耗材成本的年度实际工时总计。计算机功能的进步为CEMS功能提供了不仅变得更全面而且更强大的机会。这些进步中的关键是不仅可以为软件平台提供工厂支持服务,而且现在甚至可以降低分析仪本身的基本审核参数的能力。现在,第三代CEMS可以从仪器维修店,供应商的工厂或公司的技术服务中心远程访问分析仪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号