A series of investigations were conducted to evaluate the precision and accuracy of crude protein assays at 72 commercial feed companies. Results indicated a significant opportunity to improve accuracy and precision of analyses in many laboratories. Also, it was found that the Kjeldahl procedure detects 14.3 g/kg less protein on average than does the Dumas (combustion) procedure. This difference was most pronounced in higher protein samples. The use of- nicotinic acid and L-tryptophan reference standards were examined in 12 of the laboratories. Results suggest that digestion of samples during the Kjeldahl procedure is incomplete a majority of laboratories. The value of laboratory errors in protein analysis was estimated to be significant. With respect to feed formulation alone, losses as high as $280,000 were estimated assuming 20,000 mt per month of feed produced and an error in protein analysis of soybean meal of 14.1 g/kg.
机译:进行了一系列调查,以评估72家商业饲料公司中粗蛋白测定的准确性和准确性。结果表明在许多实验室中提高分析准确性和精确度的重要机会。而且,发现凯氏定氮法比杜马法(燃烧法)平均检测到的蛋白质少14.3 g / kg。这种差异在高蛋白样品中最为明显。在12个实验室中检查了烟酸和L-色氨酸参考标准品的使用。结果表明,凯氏定氮法在样品消化过程中大多数实验室是不完整的。蛋白质分析中实验室错误的价值估计很重要。仅就饲料配方而言,假设每月生产的饲料为20,000公吨,大豆粉蛋白质分析误差为14.1 g / kg,则估计损失高达280,000美元。