There is a strong need to improve our current capabilities in thermal management and electronic cooling, since estimates indicate that IC power density level could reach 50 W/cm~2 in near future. This paper presents several possible closed and open loop cooling schemes for thermal management of electronic equipment in data centers. Additionally, analytical modeling of two kinds of direct expansion refrigeration cooling evaporator and a secondary liquid cooling fan coil heat exchanger is incorporated with a computational fluid dynamics (CFD) model to analyze a refrigeration cooled high heat density electronic and computer data center installed on a raised floor. Both models incorporate an accurate tube-by-tube thermal hydraulic modeling of the heat exchanger. The refrigeration coil analysis incorporates a multi region heat exchanger analysis for a more precise modeling of two phase refrigerant flow in the evaporator. The single phase secondary loop fan coil heat exchanger modeling uses an effectiveness method for regional modeling of the spot-cooling coil. Using an iterative method, results of the heat exchanger modeling is simultaneously incorporated in the CFD model and an optimal design of spot cooling heat exchanger is developed.
机译:迫切需要提高我们目前在热管理和电子冷却方面的能力,因为估计表明IC功率密度水平可能在不久的将来达到50 W / cm〜2。本文提出了几种可能的闭环和开环冷却方案,用于数据中心电子设备的热管理。此外,将两种直接膨胀式制冷冷却蒸发器和辅助液体冷却风扇盘管热交换器的分析模型与计算流体动力学(CFD)模型相结合,以分析安装在高架上的制冷冷却高热密度电子和计算机数据中心地板。两种模型均包含热交换器的精确的逐管热液模型。制冷盘管分析结合了多区域换热器分析,可以更精确地模拟蒸发器中两相制冷剂的流动。单相次级环流风机盘管换热器建模使用一种有效方法对局部冷却盘管进行区域建模。使用迭代方法,将换热器建模的结果同时纳入CFD模型中,并开发了点冷却换热器的优化设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号