【24h】

PIV Measurement of the Exhaled Flow from Breathing Thermal Manikin

机译:呼吸热人体模型呼出气流的PIV测量

获取原文
获取原文并翻译 | 示例

摘要

Human respiration can act as contaminant source,while few studies were found in literature on the exhaled flow characteristic.For the exhaled flow is periodic and transient,the mean velocity is obtained by phase-averaged not time-averaged.In the paper,the PIV technique is used to study the exhaled flow characteristics.Experiment is carried on isothermal and non-isothermal conditions.The experiment indicated Compared with isothermal condition,the exhaled flow is upwards somewhat in the early stage,and most of the jet keeps horizontal.What is more,the jet region is larger in the non-isothermal conditions.Some turbulent characteristics are also obtained in the non-isothermal condition.The exhaled flow is highly turbulent.In a period,the turbulent intensity is relatively low in the early stage,while it is high in the middle and end stage.The vorticity of exhaled flow is quite large,and the value experiences a change along with the phase change.The vorticity shows unsymmetrical with the centerline somewhat.
机译:人的呼吸可能是污染物的来源,而文献中关于呼气流动特性的研究很少。由于呼气流动是周期性的和瞬时的,因此平均速度是通过相位平均而不是时间平均来获得的。在等温和非等温条件下进行了实验。实验表明,与等温条件相比,早期的呼气流量略有上升,大部分射流保持水平。另外,在非等温条件下,射流区域更大。在非等温条件下,也获得了一些湍流特性。呼出气流是高度湍流的。在一段时间内,早期的湍流强度相对较低,而呼出气流的涡度相当大,其值随相变而变化。涡度与中心不对称。特林有点。