Thermal properties of thin films may differ from the bulk value due to the differences in microstructure, such as the grain size, impurities and defects. Heat capacity is one of the thermophysical properties and it is measured by calorimetry. However, traditional calorimeters can't measure heat capacity of thin films which are quasi-2D and has small heat capacity. Recently, micro calorimeters with suspending membrane structure have been developed to measure the heat capacity of ultra thin films with thickness of sub-micrometer to nanometer scale. Efforts are focused on reducing heat capacitance of the addenda and minimizing the thermal link so as to permit an adiabatic measurement of the heat capacity of thin film. In this paper, a micro pulse calorimeter was developed and heat capacities of the copper thin films were measured by the micro pulse calorimetry. The heating rate of the micro calorimeter is up to 200K/ms with heating power of 4.5mW, and the heat capacity of the calorimeter is about 23.4nJ/K at 300K. Heat capacities of polycrystalline copper thin films with thickness from 20nm to 340nm were measured in the temperature range from 300K to 420K in vacuum of 1mPa. In order to extract the specific heat of the Cu films, mass of the films was calculated with volume and density of the sample film. The specific heat of the Cu films was compared with the literature values of bulk Cu. The specific heat of the 340nm Cu film is close to the literature data of bulk Cu. For the thinner films, enhanced specific heat was observed, and the data shows that the specific heat increases with the decreasing of crystalline size and film thickness.
机译:由于微观结构的差异(例如晶粒尺寸,杂质和缺陷),薄膜的热性能可能与体积值不同。热容量是热物理性质之一,并且通过量热法测量。但是,传统的量热仪无法测量准2D薄膜且热容较小的薄膜的热容。最近,已经开发了具有悬浮膜结构的微热量计,以测量亚微米至纳米级厚度的超薄膜的热容量。努力集中在减小附加件的热电容和使热链接最小化,以允许绝热测量薄膜的热容量。本文开发了一种微脉冲量热仪,并通过微脉冲量热法测量了铜薄膜的热容。微型量热仪的加热速率高达200K / ms,加热功率为4.5mW,在300K时的热容量约为23.4nJ / K。在1mPa的真空中,在300K至420K的温度范围内测量厚度为20nm至340nm的多晶铜薄膜的热容量。为了提取Cu膜的比热,通过样品膜的体积和密度来计算膜的质量。将Cu膜的比热与块状Cu的文献值进行比较。 340nm Cu薄膜的比热接近于块状Cu的文献数据。对于较薄的膜,观察到增强的比热,并且数据表明,随着晶体尺寸和膜厚度的减小,比热增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号