Revascularization procedure for peripheral artery disease is dependent on surgeon's skill and experience for a successful procedure. An integrated sensor on guidewire is proposed to reduce such dependency during the procedure. The development and packaging of the sensor with a hybrid-silicone-polymer substrate (HSPS) and a silicon stopper arepresented in this paper. A compact HSPS (0.4mm x 10mm x0.31mm) with trace width/spacing of 20μm/20μm for five output signals and Si stopper with safety displacement feature to prevent force overloading are fabricated. It is able to enhanced current sensor integrated guidewire by improving the robustness and provides a forward sensing mechanism (orthogonal assembly). The assembled device is able to measure up till 42mN force with a resolution of 0.2mN. Detail of characterization testing and result will be presented in the paper.
机译:外周动脉疾病的血运重建术取决于外科医生的技能和成功手术的经验。建议在导丝上集成传感器以减少手术过程中的这种依赖性。本文介绍了带有混合有机硅聚合物衬底(HSPS)和硅塞的传感器的开发和包装。制作了紧凑的HSPS(0.4mm x 10mm x0.31mm),其迹线宽度/间距为20μm/20μm(用于五个输出信号),并具有带安全位移功能的Si挡块,可防止力过载。它能够通过提高鲁棒性来增强集成电流传感器的导线,并提供正向传感机制(正交装配)。组装后的设备能够测量高达42mN的力,分辨率为0.2mN。表征测试的细节和结果将在本文中介绍。