A power-series trend curve of elapsed time was estimated by using time series data of measured concentrations of carbon monoxide in the Taiheiyo coal mine, Hokkaido, Japan. The difference between the moving average concentration data and the estimated data from the trend curve showed linear correlation when plotted on a normal probability paper and a correlation coefficient value of 0.99. It is concluded that the estimate of carbon monoxide concentration using moving average values of concentrations compares very well with the results obtained from the trend curve within the three-sigma (standard deviation) range of the distribution. Thus, it is believed the results can be used to monitor and detect abnormal ventilation conditions in a ventilation network such as the occurrence of spontaneous combustion at an early stage.
机译:通过使用日本北海道太平代煤矿的一氧化碳浓度实测时间序列数据,估算了经过时间的幂级数趋势曲线。当在正态概率纸上绘制时,移动平均浓度数据与趋势曲线估计数据之间的差异显示线性相关,且相关系数值为0.99。结论是,使用浓度的移动平均值对一氧化碳浓度的估计与从分布的三西格玛(标准差)范围内的趋势曲线获得的结果非常吻合。因此,据信该结果可用于监测和检测通风网络中的异常通风状况,例如在早期发生自燃。