首页> 外文会议>2017 IEEE 2nd Information Technology, Networking, Electronic and Automation Control Conference >Experimental study of partial discharge pulses propagation in stator winding of hydro generator
【24h】

Experimental study of partial discharge pulses propagation in stator winding of hydro generator

机译:水轮发电机定子绕组中局部放电脉冲传播的实验研究

获取原文
获取原文并翻译 | 示例

摘要

The propagation of PD pulses through the winding, from the discharge site to the sensor location, is influenced by the frequency of signal and the geometry of generator, which is of critical importance for accurate measurement of the PD signals. The previous researches on PD propagation were mainly made on turbine generator or motor, little work had been done on hydro generator. To address this concern, an experimental study of the propagation of PD pulses in the stator winding of a large hydro generator is presented in this paper. In the test, the insulation outside slot exit of 22 bars was removed to directly inject PD pulses to the inner conductor. The results indicated PD signals manifest two modes when propagating in stator winding of large hydro generator, and 5MHz is the corner frequency of them. The coupling between bars in slot or overhang will cause crosstalk between phases, which obscures PD source location.
机译:PD脉冲通过绕组从放电位置到传感器位置的传播受到信号频率和发生器几何形状的影响,这对于精确测量PD信号至关重要。以前关于局部放电传播的研究主要是在涡轮发电机或电动机上进行的,而在水力发电机上所做的工作很少。为了解决这个问题,本文对大型水轮发电机的定子绕组中PD脉冲的传播进行了实验研究。在测试中,去除了22巴的槽外绝缘层,以将PD脉冲直接注入内部导体。结果表明,PD信号在大型水轮发电机定子绕组中传播时表现出两种模式,其转折频率为5MHz。插槽或悬垂中的条之间的耦合将导致相位之间的串扰,这会掩盖PD源的位置。