The paper mainly described the upgrade study of UHVDC converter valve type test capability, which will meet all the test requirements of ± 800kV/6250A and ±1100kV/5454A thyristor valves. By optimizing and upgrading rectifier transformer and water-cooled systems, especially that a new synthetic fault test circuit, the operational test capability reaches rated current 7500 A, and fault current peak is 62 kA. In addition, surface electric field intensity on shielding cases of the impulse test equipment is calculated by using Galerkin boundary element method. According to existing conditions, a feasible measure is proposed, which can be employed to decrease electric field dramatically and avoid corona discharge of shielding cases. Another effort in the dielectric test is theoretically analysis and test study for the DC test equipment with rated voltage ±2400kV. Finally, the parameters and results for the ± 800kV/6250A and ±1100kV/5454A prototype will be presented.
机译:本文主要介绍了特高压直流换流阀类型试验能力的升级研究,该试验将满足±800kV / 6250A和±1100kV / 5454A晶闸管阀的所有测试要求。通过优化和升级整流变压器和水冷系统,特别是新的综合故障测试电路,其工作测试能力达到了额定电流7500 A,故障电流峰值为62 kA。另外,采用Galerkin边界元法计算了脉冲试验设备的屏蔽盒表面电场强度。根据现有条件,提出了一种可行的措施,可以大幅度减小电场,避免屏蔽盒的电晕放电。介电测试的另一项工作是对额定电压为±2400kV的直流测试设备进行理论分析和测试研究。最后,将给出±800kV / 6250A和±1100kV / 5454A原型的参数和结果。