首页> 外文会议>2013 IEEE International Conference on Medical Imaging Physics and Engineering >The observation of hip joint cartilage of elderly people based on EPIC Micro-CT
【24h】

The observation of hip joint cartilage of elderly people based on EPIC Micro-CT

机译:基于EPIC Micro-CT的老年人髋关节软骨的观察

获取原文
获取原文并翻译 | 示例

摘要

The objective of this study was to observe the age-related changes of sulfated glycosaminoglycan (sGAG) content and surface roughness of hip joint cartilage of elderly people based on Equilibrium Partitioning of an Ionic Contrast Agent (EPIC) Micro-CT. 35 human hip cartilage-bone samples were prepared from hip-fracture patients whose age were from 50 to 100 years old and divided into 5 groups (10 years as an age group). They were first immersed in 20% concentration of the contrast agent Meglumine Diatrizoate (MD) for 6 hours at 37°C, and scanned by Micro-CT after taken out from the contrast agent. The X-ray mean attenuation and hip joint cartilage surface roughness were calculated. The results showed the X-ray mean attenuation of the entire hip joint cartilage increased about 17.44% from the 50 age group to the 80 age group (from 1294.61±97.77HU to 1520.39±184.56HU), but it decreased about 6.43% in the 90 age group compared to the 80 age group (from 1520.39±184.56HU to 1422.55±106.37HU). Moreover, the X-ray mean attenuations of the superficial layer, middle layer and radical layer of cartilage declined successively in the different age groups. Regarding of the superficial layer and middle layer from the 50 age group to the 80 age group, they rose about 31.21 % and 43.02% respectively (from 1472.40±138.96HU to 1931.99±199.69HU and 1271.83±58.36HU to 1819.07±213.55HU), and also reduced 4.64% and 6.03% separately in the 90 age group (from 1931.99±199.69HU to 1798.12±153.32HU, and 1819.07±213.55HU to 1653.22±169.46HU), while the radical layer showed no significant change along with age increase. The hip joint cartilage surface roughness changes only 5.31% with age increase (from 13.64±5.17μm to 14.36±5.21μm).
机译:这项研究的目的是基于离子造影剂(EPIC)Micro-CT的平衡分配,观察老年人的髋关节软骨硫酸化糖胺聚糖(sGAG)含量和表面粗糙度的年龄变化。从年龄在50至100岁之间的髋部骨折患者中制备了35例人类髋关节软骨骨样品,并分为5组(年龄组为10岁)。首先将它们浸入37%的浓度为20%的造影剂Meglumine Diatrizoate(MD)中6小时,然后从造影剂中取出后用Micro-CT扫描。计算X射线平均衰减和髋关节软骨表面粗糙度。结果表明,从50岁年龄组到80岁年龄组,整个髋关节软骨的X射线平均衰减量增加了约17.44%(从1294.61±97.77HU降至1520.39±184.56HU),但在整个年龄段下降了约6.43%。 90岁年龄段与80岁年龄段相比(从1520.39±184.56HU到1422.55±106.37HU)。而且,不同年龄组的软骨表层,中层和根治层的X射线平均衰减量依次下降。从50岁年龄段到80岁年龄段的表层和中间层,分别上升了约31.21%和43.02%(从1472.40±138.96HU到1931.99±199.69HU和1271.83±58.36HU到1819.07±213.55HU) ,并且在90岁年龄段(分别从1931.99±199.69HU至1798.12±153.32HU和1819.07±213.55HU至1653.22±169.46HU)中分别降低了4.64%和6.03%。增加。髋关节软骨表面粗糙度随年龄的增长而变化仅为5.31%(从13.64±5.17μm增至14.36±5.21μm)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号