Different abnormal appearances would usually be observed on dies of failed devices after decapsulation. In this paper, cases of failure analysis on typical abnormal appearances were introduced, such as discoloration region observed by metallographic microscope, fused/arching lines, common burnout of metallization on surface and uncovered by Photon Emission Microscope (EMMI) result, etc. It showed a simple and distinct way to study on the causation of abnormal appearances based on Focused Ion Beam (FIB) milling technology. Meanwhile the advantage of strong applicability was presented also.
机译:解封后,在故障器件的管芯上通常会观察到不同的异常外观。本文介绍了典型异常现象的失效分析案例,如金相显微镜观察到的变色区域,熔合/弓形线,表面常见的金属镀层烧坏和光子发射显微镜(EMMI)结果未发现的情况等。一种基于聚焦离子束(FIB)铣削技术的异常现象原因的简单而独特的研究方法。同时还提出了适用性强的优点。