This paper presents the results of shaft voltages measurement campaign undertaken to investigate the sources of unrecoverable temperature drift observed on the thrust bearing of a small industrial steam turbine of a turbogenerator installed in a cogeneration biomass thermal power station. The bandwidth of the shaft voltage signal recorded and the characteristic time evolution have pointed out the electrostatic charges produced by the turbine steam as the source of the shaft voltage. The study have shown that in this specific plant dangerous shaft voltages can settle in case of a bad shaft to ground connection, originally assured by a grounding brush installed inside the turbine bearing casing only.
机译:本文介绍了轴电压测量活动的结果,该结果旨在调查在热电联产生物质热电厂中安装的小型发电机的工业蒸汽轮机的推力轴承上观察到的不可恢复的温度漂移的来源。所记录的轴电压信号的带宽和特征性的时间演变指出了由涡轮蒸汽产生的静电荷作为轴电压的来源。研究表明,在该特定工厂中,如果轴与地面之间的连接不良,则危险的轴电压会稳定下来,最初只能通过安装在涡轮机轴承箱内部的接地刷来确保。