Seismic proving tests were conducted to verify the effect of energy absorbing supports developed for application to nuclear power plant piping systems. Main steam and feedwater pipings inside the containment vessel have the important function of carrying reactor coolant and were selected for the test model with scaling of 1:2.3. The test model had two kinds of typical energy absorbing supports. One was EAB(Energy Absorber) utilizing X-shaped steel plates' elasto-plastic deformation. The other was LED(Lead Extrusion Damper) utilizing plastic deformation of internal lead. The response wave for design earthquake used to construct actual PWR plants was selected as the input wave used in the test, and it was the strictest possible wave for the test model. In the design of the test model, we employed response spectrum analysis which employs iterative calculation of EAB displacements using each mode's damping ratio. We determined location and capacity of supports and pipe stress to meet the current design standard based on the analysis results.rnThis paper reports the validity of the design analysis method for piping systems supported by energy absorbing supports andrnits effect based on an evaluation and comparison of analysis results with test results for the test model of the F-line.
机译:进行了抗震测试,以验证开发用于核电站管道系统的吸能支架的效果。安全壳内的主要蒸汽和给水管道具有运送反应堆冷却剂的重要功能,并按1:2.3的比例选择用于测试模型。该测试模型具有两种典型的能量吸收支架。一种是利用X形钢板的弹塑性变形的EAB(能量吸收器)。另一个是利用内部引线的塑性变形的LED(Lead Extrusion Damper)。选择用于建造实际压水堆电厂的设计地震响应波作为测试中使用的输入波,这是测试模型中最严格的波。在测试模型的设计中,我们采用了响应谱分析,该分析利用每种模式的阻尼比对EAB位移进行迭代计算。根据分析结果,确定了支座的位置和承载力以及管道应力是否满足现行设计标准。rn本文通过对评估和比较的分析,总结了吸能支座支护系统设计分析方法的有效性和影响结果以及F线测试模型的测试结果。

著录项

  • 来源
  • 会议地点 Nice(FR);Nice(FR)
  • 作者单位

    Hitachi Works, Hitachi, Ltd.1-1, Saiwai-cho 3-chome, Hitachi-shi, Ibaraki-ken, 317, Japan TEL 81-294-23-5342, FAX 81-294-23-6612;

    rnMechanical Engineering Research Lab., Hitachi, Ltd. 502 Kandatsu-cho, Tsuchiura-shi, Ibaraki-ken, 300, Japan TEL 81-298-32-4111, FAX 81-298-32-2808;

    rnTokyo Metropolitan University 1-1, Minamiosawa, Hachioji-shi, Tokyo, 193-03, Japan TEL 81-426-77-2703, FAX 81-426-77-2701;

    rnNuclear Power Engineering Corporation 4-3-13, Toranomon, Minato-ku, Tokyo, 105, Japan TEL 81-3-3434-4551, FAX 81-3-3434-9487;

    rnNuclear Power Engineering Corporation 4-3-13, Toranomon, Minato-ku, Tokyo, 105, Japan TEL 81-3-3434-4551, FAX 81-3-3434-9487;

    rnNuclear Power Engineering Corporation 4-3-13, Toranomon, Minato-ku, Tokyo, 105, Japan TEL 81-3-3434-4551, FAX 81-3-3434-9487;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 核反应堆工程;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号