首页> 外文会议>14th International Conference on Nuclear Engineering 2006(ICONE14) vol.1 >Instantaneous Leakage Evaluation of Metal Cask at Drop Impact
【24h】

Instantaneous Leakage Evaluation of Metal Cask at Drop Impact

机译:跌落冲击下金属桶的瞬时泄漏评估

获取原文
获取原文并翻译 | 示例

摘要

There have been a lot of tests and analyses reported for evaluation of drop tests of metal casks. However, no quantitative measurement has ever been made for any instantaneous leakage through metal gaskets during the drop tests due to loosening of the bolts in the containments and lateral sliding of the lids.rnIn order to determine a source term for radiation exposure dose assessment, it is necessary to obtain fundamental data of instantaneous leakage.rnIn this study, leak tests were performed by using scale models of the lid structure and a full scale cask without impact limiters simulating drop accidents in a storage facility, with aim of measuring and evaluating any instantaneous leakage at drop impact.rnPrior to drop tests of a full scale metal cask, a series of leakage tests using scale models were carried out to establish the measurement method and to examine a relationship between the amount of the lateral sliding of the lid and the leak rate. It was determined that the leak rate did not depend on the lateral sliding speeds.rnDrop tests of a full scale metal cask without impact limiters were carried out by simulating drop accidents during handling in a storage facility. The target was designed to simulate a reinforced concrete floor in the facility. The first test was a horizontal drop from a height of 1 m. The second test simulated a rotational impact around an axis of a lower trunnion of the cask from the horizontal status at a height of 1 m.rnIn the horizontal drop test, the amount of helium gas leakage was calculated by integrating the leak rate with time. The total amount of helium gas leakage from the primary and secondary lids was 1.99x10~(-6)Pa • m~3. This value is 9.61x10~(-9)% of the initially installed helium gas. The amountrnof leakage was insignificant. In the rotational drop test, the total amount of leakage from the primary and secondary lids was 1.74x10~(-5)Pa • m~3. This value is 8.45x10~(-8)% of the initially installed helium gas. This value was larger than that of the horizontal drop test. Nevertheless, the amount of leakage was also insignificant. The relationship between the maximum sliding displacement of the lid and the leak rate coincided between the tests of a scale model and a full scale metal cask.
机译:有许多测试和分析报告用于评估金属桶的跌落测试。但是,由于安全壳中螺栓的松动和盖子的侧向滑动,在跌落测试中从未对金属垫片的任何瞬时泄漏进行定量测量。为了确定辐射暴露剂量评估的源项,为了获得瞬时泄漏的基本数据是必需的。在这项研究中,使用盖结构的比例模型和不带冲击限制器的满刻度桶进行泄漏测试,以模拟存储设施中的跌落事故,目的是测量和评估任何瞬时泄漏跌落冲击时的泄漏。在满刻度金属桶的跌落测试之前,使用比例尺模型进行了一系列泄漏测试,以建立测量方法并检查盖子的侧向滑动量与泄漏之间的关系。率。确定泄漏率不取决于横向滑动速度。通过模拟在存储设施中搬运过程中的跌落事故,对没有冲击限制器的全尺寸金属桶进行了落下测试。该目标旨在模拟设施中的钢筋混凝土地板。第一个测试是从1 m的高度水平下降。第二项测试模拟了在1 m高度处从水平状态绕着桶下部耳轴的旋转冲击。在水平跌落测试中,通过将泄漏率与时间进行积分来计算氦气泄漏量。从第一和第二盖泄漏的氦气总量为1.99x10〜(-6)Pa•m〜3。该值是初始安装的氦气的9.61x10〜(-9)%。泄漏量微不足道。在旋转跌落试验中,从第一盖和第二盖泄漏的总量为1.74x10〜(-5)Pa•m〜3。该值是初始安装的氦气的8.45x10〜(-8)%。该值大于水平跌落试验的值。但是,泄漏量也很小。盖子的最大滑动位移和泄漏率之间的关系在比例模型和满刻度金属桶的测试之间重合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号