【24h】

Wastewater with low C/N ratio treated by partial nitrification/anammox process

机译:部分硝化/厌氧氨氧化工艺处理低碳氮比废水

获取原文

摘要

Using synthetic wastewater and sludge dewatering effluent as influent, respectively, wastewater with low C/N ratio treated by partial nitrification/anammox process was investigated. The results showed that half partial nitrification can be accomplished in CSTR at DO of 0.5-1.0 mg/L and HRT of 24h, the average effluent ratio of NO2 --N/NH4 +-N maintained at about 1.25 and the average effluent ratio of [NO2 --N]/[Nox --N] kept above 97.52%. The partial nitrification/anammox process was suitable to treat wastewater with low C/N ratio. When synthetic wastewater was treated, TN removal percent of 87.53% was obtained. When sludge dewatering effluent was treated, the total nitrogen removal loading rate was up to 0.143 kg/m3·d with TN removal percent of 86.82% and COD removal percent of 84.88% after 29d operation. When wastewater with low C/N ratio was treated by partial nitrification/anammox process, nitrogen was mostly removed through anammox reactor while organic matter was mostly removed through partial nitrification reactor.
机译:以合成废水和污泥脱水废水为进水,研究了部分硝化/厌氧氨氧化工艺处理低碳氮比废水。结果表明,在CSTR中,DO为0.5-1.0 mg / L,HRT为24h时可以完成半部分硝化反应,NO2-N / NH4 + -N的平均出水率保持在1.25左右,NH4-N的平均出水率保持在1.25。 [NO 2 -N] / [NOx -N]保持在97.52%以上。部分硝化/厌氧氨氧化工艺适合处理低C / N比的废水。处理合成废水后,总氮去除率为87.53%。处理污泥脱水废水后,运行29d后总氮去除率达到0.143 kg / m3·d,总氮去除率86.82%,化学需氧量去除率84.88%。当通过部分硝化/厌氧氨氧化工艺处理低C / N比的废水时,氮大部分通过厌氧氨氧化反应器去除,而有机物则大部分通过部分硝化反应器去除。