首页> 外文OA文献 >Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry
【2h】

Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry

机译:为免疫抑制剂通过液相色谱串联质谱法测定的全血样品的自动处理

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Methods: Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. Results: A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 mu g/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. Conclusions: The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.
机译:背景:液相色谱串联质谱法(LC-MS / MS)是一种常规测定全血中免疫抑制剂的有效技术。但是,费时的手动样品制备仍然是该技术的重大局限。方法:使用市售的自动移液系统(Tecan Freedom EVO),我们开发了一种自动样品制备方案,用于通过LC-MS / MS定量全血中他克莫司的含量。通过自动系统执行条形码读取,样品重悬,将全血等分试样转移到深孔板中,添加内标溶液,混合以及通过添加有机溶剂进行蛋白质沉淀。离心板后,在LC-MS / MS分析之前,使用色谱柱切换将脱蛋白的上清液进行在线固相萃取。在整个过程中,唯一的手动操作是将试管开盖,并将深孔板从机器人系统转移到离心机,最后转移到HPLC自动进样器。全血池用于评估用于测量他克莫司浓度的整个分析系统的重现性。结果:在整个自动化分析过程中,总变异系数为1.7%(n = 40;他克莫司平均浓度为5.3μg/ L)。观察到他克莫司在手动和自动样品制备后获得的结果之间的一致性。结论:这里描述的分析系统,包括自动蛋白质沉淀,在线固相萃取和LC-MS / MS分析,方便而精确,并最大限度地减少了动手时间和全血免疫抑制剂定量错误的风险浓度与常规方法相比。

著录项

  • 作者

    Vogeser Michael; Spöhrer Ute;

  • 作者单位
  • 年度 2006
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号