首页> 美国政府科技报告 >Densified Refuse-Derived Fuel (d-RDF) Burn at Marcy Psychiatric Center
【24h】

Densified Refuse-Derived Fuel (d-RDF) Burn at Marcy Psychiatric Center

机译:密集的垃圾衍生燃料(d-RDF)在marcy精神病中心烧伤

获取原文

摘要

A densified refuse derived fuel (d-RDF) product was fired for approximately 50 hours as a supplemental fuel in a coal fired spreader stoker boiler at the Marcy Psychiatric Center in Marcy, New York. Observations were made and photographs were taken of plant operation during all phases of the test project. Opacity and particulate emission tests were performed while firing d-RDF in a ratio of 1:2 with coal (by volume) and while firing 100 percent coal at high and low loads to provide comparisons with State Department of Environmental Conservation emission standards. No significant disadvantages over coal were found in burning d-RDF/coal in ratios up to 2:1 (43 percent heat input by d-RDF). Fuel handling, boiler operation, boiler efficiency, particulate emissions and opacity were similar for the coal and d-RDF/coal mixtures.