首页> 美国政府科技报告 >Heat Transfer and Pressure Drop Performance of a Finned-Tube Heat Exchanger Proposed for Use in the NASA Lewis Altitude Wind Tunnel
【24h】

Heat Transfer and Pressure Drop Performance of a Finned-Tube Heat Exchanger Proposed for Use in the NASA Lewis Altitude Wind Tunnel

机译:建议用于Nasa Lewis海拔风洞的翅片管换热器的传热和压降性能

获取原文

摘要

A segment of the heat exchanger proposed for use in the NASA Lewis Altitude Wind Tunnel (AWT) facility has been tested under dry and icing conditions. The heat exchanger has the largest pressure drop of any component in the AWT loop. It is therefore critical that its performance be known at all conditions before the final design of the AWT is complete. The heat exchanger segment is tested in the NASA Lewis Icing Research Tunnel (IRT) in order to provide an icing cloud environment similar to what will be encountered in the AWT. Dry heat transfer and pressure drop data are obtained and compared to correlations available in the literature. The effects of icing sprays on heat transfer and pressure drop are also investigated.