首页> 美国政府科技报告 >Mechanical Integrity Issues at MCM-Cs for High Reliability Applications
【24h】

Mechanical Integrity Issues at MCM-Cs for High Reliability Applications

机译:mCm-C的高可靠性应用中的机械完整性问题

获取原文

摘要

During the qualification of a new high reliability low-temperature cofired211u001eceramic (LTCC) multichip module (MCM), two issues relating to the electrical and 211u001emechanical integrity of the LTCC network were encountered while performing 211u001equalification testing. One was electrical opens after aging tests that were 211u001ecaused by cracks in the solder joints. The other was fracturing of the LTCC 211u001enetworks during mechanical testing. Through failure analysis, computer modeling, 211u001ebend testing, and test samples, changes were identified. Upon implementation of 211u001eall these changes, the modules passed testing, and the MCM was placed into 211u001eproduction.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号