A new proton injection kicker system is required for the Tevatron in the Run IIera. The new system was designed to supply 1.25 kG-m into a magnetic aperture of 48 mm vertical x 71 mm horizontal x 5 m long with a 396 ns bunch spacing. The system was designed to be upgraded to 132 ns bunch spacing with additional pulse supplies. The design of the magnet incorporated some novel features in order to meet these requirements. These include adjustable bus spacing to set the inductance and balanced positive and negative high voltage buses. This system has been installed in the Tevatron.