Since the mid-1970s, various high temperature gas-cooled reactor (HTGR) steam generator, auxiliary heat exchanger (AHE), recuperator, and intermediate heat exchanger (IHX) designs have been proposed that use straight tube configurations. Each of these designs requires 90-deg turns in the helium gas flow at the inlet and/or outlet of the tube bundle. To evaluate the effect of these turns on the tube bundle performance, two model air flow tests have been performed, and a third is being planned. Fluid flow and heat transfer computer models have also been used to try to determine the effect of these 90-deg turns on the tube bundle performance. (ERA citation 09:025921)