首页> 美国政府科技报告 >10 MWe Solar Thermal Central Receiver Pilot Plant Mode 5 (Test 1150) and Mode 6 (Test 1160) Test Report
【24h】

10 MWe Solar Thermal Central Receiver Pilot Plant Mode 5 (Test 1150) and Mode 6 (Test 1160) Test Report

机译:10 mWe太阳能热中央接收器试验工厂模式5(测试1150)和模式6(测试1160)测试报告

获取原文

摘要

The purpose of this report is to document the test results and conclusions pertinent to operating Mode 5 (charging only) and Mode 6 (extraction) of the Thermal Storage Subsystem of Solar One. Mode 5 was demonstrated successfully, particularly during periods of cloud passages over the sun. Dual charging train testing, while successful, revealed that dual train operation was not often necessary or desirable. Mode 6 testing was demonstrated for both single and dual train operation; stable single train operation was demonstrated at 0.7 MWe (gross). The extractable energy capacity of the Thermal Storage Unit was demonstrated to exceed the design requirements during Mode 6 testing. (ERA citation 11:035769)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号