首页> 外文期刊>Physics in medicine and biology. >Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer.
【24h】

Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer.

机译:快速千伏/兆电压(kVMV)呼吸锥束CT用于肺癌的图像引导放射治疗。

获取原文
获取原文并翻译 | 示例
           

摘要

Long image acquisition times of 60-120 s for cone-beam CT (CBCT) limit the number of patients with lung cancer who can undergo volume image guidance under breathhold. We developed a low-dose dual-energy kilovoltage-megavoltage-cone-beam CT (kVMV-CBCT) based on a clinical treatment unit reducing imaging time to < or =15 s. Simultaneous kVMV-imaging was achieved by dedicated synchronization hardware controlling the output of the linear accelerator (linac) based on detector panel readout signals, preventing imaging artifacts from interference of the linac's MV-irradiation and panel readouts. Optimization was performed to minimize the imaging dose. Single MV-projections, reconstructed MV-CBCT images and images of simultaneous 90 degrees kV- and 90 degrees MV-CBCT (180 degrees kVMV-CBCT) were acquired with different parameters. Image quality and imaging dose were evaluated and compared to kV-imaging. Hardware-based kVMV synchronization resulted in artifact-free projections. A combined 180 degrees kVMV-CBCT scan with a total MV-dose of 5 monitor units was acquired in 15 s and with sufficient image quality. The resolution was 5-6 line pairs cm(-1) (Catphan phantom). The combined kVMV-scan dose was equivalent to a kV-radiation scan dose of approximately 33 mGy. kVMV-CBCT based on a standard linac is promising and can provide ultra-fast online volume image guidance with low imaging dose and sufficient image quality for fast and accurate patient positioning for patients with lung cancer under breathhold.
机译:锥形束CT(CBCT)的60-120 s的长图像采集时间限制了在屏气状态下可以接受体积图像指导的肺癌患者数量。我们基于临床治疗单元开发了一种低剂量双能千伏千伏-锥束CT(kVMV-CBCT),可将成像时间缩短至<或= 15 s。通过专用同步硬件,基于检测器面板读数信号控制线性加速器(linac)的输出,可以同时实现kVMV成像,从而防止成像伪影受到直线加速器MV辐射和面板读数的干扰。进行了优化以最小化成像剂量。使用不同的参数获取单个MV投影,重构的MV-CBCT图像以及同时进行90度kV和90度MV-CBCT(180度kVMV-CBCT)的图像。评估图像质量和成像剂量,并将其与kV成像进行比较。基于硬件的kVMV同步可实现无伪影的投影。在15 s内获得了具有5个监视单元的总MV剂量的180度kVMV-CBCT组合扫描,并且具有足够的图像质量。分辨率为5-6线对cm(-1)(Catphan幻影)。组合的kVMV扫描剂量等于大约33 mGy的kV辐射扫描剂量。基于标准直线加速器的kVMV-CBCT是有前途的,它可以以低成像剂量和足够的图像质量提供超快速的在线体图像指导,以快速准确地定位呼吸中的肺癌患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号