Quandaries in the application of the ICNIRP low frequency basic restriction on current density

机译:在ICNIRP低频应用中限制电流密度的难题

获取原文
获取原文并翻译 | 示例
           

摘要

This paper identifies uncertainties and problems in the practical application of the ICNIRP low frequency basic restriction on current density. This quantity should be averaged over a cross-section of 1 cm(2) perpendicular to the current direction. The rationale and the sensitivity of the current density average are investigated. There are difficulties in finding a square centimetre of spinal cord over which to average. The consequences of including neighbouring tissues in the averages are investigated in the male and female voxel models NORMAN and NAOMI for applied uniform electric and magnetic fields at 50 Hz. Also the case of the non-uniform magnetic field from a horizontal current carrying conductor adjacent to the back of the body is investigated. The maximum and 99th percentile current density values are compared with the 1 cm(2) average in the derivation of external field reference levels.
机译:本文确定了ICNIRP低频基本限制电流密度的实际应用中的不确定性和问题。该数量应在垂直于电流方向的1 cm(2)的横截面上求平均值。研究了电流密度平均值的原理和敏感性。很难找到一个平方厘米的脊髓来求平均值。在雄性和雌性体素模型NORMAN和NAOMI中,对施加于50 Hz的均匀电场和磁场,研究了将平均值包括在相邻组织中的后果。还研究了来自与人体背部相邻的水平载流导体产生的不均匀磁场的情况。在得出外部场参考电平时,将最大和第99个百分位电流密度值与1 cm(2)平均值进行比较。