摘要

BACKGROUND: Bone age (BA) rating is time consuming and highly rater dependent. OBJECTIVE: To adjust the fully automated BoneXpert method to agree with the manual Greulich and Pyle BA (GP BA) ratings of five raters and to validate the accuracy for short children. MATERIALS AND METHODS: A total of 1,097 left hand radiographs from 188 children with short stature, including growth hormone deficiency (44%) and Turner syndrome (29%) were evaluated. RESULTS: BoneXpert rejected 14 of the 1,097 radiographs, and deviated by more than 1.9 years from the operator BA for 27 radiographs. These were rerated blindly by four operators. Of the 27 new ratings, 26 were within 1.9 years of the automatic BA values. The root mean square deviation between manual and automatic rating was 0.72 years (95% CI 0.69-0.75). CONCLUSION: BoneXpert's ability to process 99% of images automatically without errors, and to obtain good agreement with an operator suggests that the method is efficient and reliable for short children.
机译:背景:骨龄(BA)评分是耗时且高度依赖评分者的。目的:调整全自动的BoneXpert方法,使其与五个评分者的手动Greulich和Pyle BA(GP BA)评分相一致,并验证矮个子儿童的准确性。材料与方法:评估了188名身材矮小儿童的1,097张左X线片,包括生长激素缺乏症(44%)和特纳综合征(29%)。结果:BoneXpert拒绝了1,097幅射线照相中的14幅,并与操作员BA进行了27幅射线照相相差1.9年以上。这些被四个操作员盲目地重估了。在27个新评级中,有26个处于自动BA值1.9年内。手动和自动评级之间的均方根偏差为0.72年(95%CI 0.69-0.75)。结论:BoneXpert能够自动处理99%的图像而不会出错,并且与操作员取得良好协议的能力表明,该方法对于矮个孩子来说是有效且可靠的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号