Effects of treatment with oral appliance on 24-h blood pressure in patients with obstructive sleep apnea and hypertension: a randomized clinical trial.

机译:口服矫治器对阻塞性睡眠呼吸暂停和高血压患者24小时血压的影响:一项随机临床试验。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Continuous positive airway pressure treatment has been shown to lower blood pressure (BP) in patients with obstructive sleep apnea (OSA). The aims of the present pilot study were to evaluate the potential effects of oral appliance (OA) therapy on BP, to assess various outcome BP measures, and to inform sample size calculation.Seventy-two patients with OSA and hypertension were randomly assigned to intervention with either an OA with mandibular advancement (active group) or an OA without advancement (control group). Before and after 3 months of treatment, the patients underwent nocturnal somnographic registration and 24-h ambulatory BP monitoring.Among the various BP measures, the largest trend toward effect of OA treatment was seen in 24-h mean systolic BP with a 1.8 mmHg stronger BP reduction in the active group compared with controls. A stronger trend toward effect was seen in a subgroup with baseline ambulatory daytime mean systolic BP >135/85 mmHg where the mean systolic BP fell, on average, 2.6 mmHg. Additional exclusion of patients with baseline apnea hypopnea index (AHI) ≤15 gave a significant reduction in mean systolic BP of 4.4 mmHg (P?=?0.044) in the active group compared with controls.In patients with OSA and hypertension, OA treatment had a modest trend toward effect on reducing BP. A stronger trend toward treatment effect was seen after excluding patients with normal baseline ambulatory BP. Additional exclusion of patients with baseline AHI ≤15 showed a significant treatment effect. Data to inform sample size for an adequately powered randomized study are provided.
机译:持续性气道正压治疗已显示可降低阻塞性睡眠呼吸暂停(OSA)患者的血压(BP)。这项初步研究的目的是评估口服矫治器(OA)治疗对BP的潜在影响,评估各种BP结局指标并提供样本量计算的信息。将72例OSA和高血压患者随机分配进行干预伴有下颌前移的OA(活动组)或不伴下颌的OA(对照组)。在治疗3个月之前和之后,患者均进行了夜间睡眠描记术和24小时动态BP监测。在各种BP措施中,OA治疗效果最大的趋势出现在24小时平均收缩压中,即1.8 mmHg与对照组相比,活动组的血压降低。在基线非卧床白天平均收缩压> 135/85 mmHg的亚组中观察到了更强的作用趋势,其中平均收缩压平均下降了2.6 mmHg。与对照组相比,基线期呼吸暂停低通气指数(AHI)≤15的患者被排除在外,与对照组相比,活动组的平均收缩压显着降低了4.4 mmHg(P?=?0.044)。有降低血压的适度趋势。排除基线动态血压正常的患者后,观察到更强的治疗效果趋势。基线AHI≤15的患者被进一步排除显示出显着的治疗效果。提供了用于告知样本量的数据,以进行足够有力的随机研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号