Purpose The purpose of this study was to compare the therapeutic pressure determined by an automated CPAP device (AutoCPAP) during the titration period, between nasal and oronasal mask and the residual apnea-hypopnea index (AHI) on a subsequent poligraphy performed with the established therapeutic CPAP.Methods As a retrospective study, 109 subjects with moderate and severe obstructive sleep apnea-hypopnea (apnea-hypopnea index> 15 events/h) were studied. CPAP titration was performed using an auto-titrating device.Results There was significant difference in the mean pressure delivered with autoCPAP between the group of patients using the nasal mask (mean 10.0 cmH2O+-2.0 SD) and the group
机译:目的本研究的目的是比较滴定期间鼻腔口罩和口鼻罩之间由自动CPAP设备(AutoCPAP)确定的治疗压力以及采用既定治疗方法进行的随后的放射学检查时残留的呼吸暂停低通气指数(AHI) CPAP.Methods作为一项回顾性研究,研究了109名中度和重度阻塞性睡眠呼吸暂停低通气(呼吸暂停低通气指数> 15事件/小时)的受试者。结果:使用自动面膜滴定仪进行CPAP滴定。结果使用鼻罩(平均10.0 cmH2O + -2.0 SD)的患者组与使用autoCPAP的平均压力组之间存在显着差异。